The Sentinel Vacuum Controller
helps maintain a stable and consistent vacuum essential to proper functioning of
a milking system.
A vacuum controller or regulator is
used in many types of vacuum systems to set and control vacuum at a desired
level. The objective of a vacuum controller is to maintain a constant vacuum
regardless of the flow in the system. The
Sentinel Vacuum Controller
is a diaphragm-operated
pneumatic valve. The Sentinel is not load sensitive to normal CFM usage. This
means, that as changes take
place in the system, the Sentinel will automatically compensate for the changing load. The
Sentinel has a fully-open to fully-closed span of .2" mercury Hg. This means that
when the vacuum rises or falls more than .2" mercury Hg, the controller will open to
maximum or it will close.
|
Get
an Email right now
regarding our vacuum controllers. Their specifications,
pricing, etc. Click below.
 |
Use Sentinel
as
your primary vacuum controller to maintain the most stable &
consistent vacuum in your vacuum system. The Sentinel has
set the highest standard of vacuum control for over 36 years.
Use
Sentinel with
existing Variable Frequency Drive systems to provide 1) security; 2) a stand-by
or secondary vacuum controller; 3) control for wash-up; 4)
a secondary relief valve.
|
The Best Way to
Control Vacuum on a Dairy Farm
|
A dairy operation can substantially improve its
vacuum system efficiencies by doing the following:
-
Proper and periodic maintenance of
the vacuum controller
-
Proper sizing of the vacuum pump
within the system
Proper placement of the vacuum
controller in the system
Many users of
various types of vacuum systems have specifically switched to our controllers to
obtain better vacuum control.
Our Sentinel
line of Vacuum Controllers, which have
been designed for dairy farm use, have also been used successfully in: pneumatic
conveying systems, vacuum
hold-down, pick and place, mail distribution systems, whey production, poultry systems,
laminate systems, printing systems, various systems
using a pressure controller, soil vapor extraction, manure handling systems, cheese processing,
central vacuum systems, router systems, dental systems and woodworking
systems.
-
Allows a pre-set vacuum level to be maintained with + or - .2"
mercury Hg over an adjustable range of 10"-15" mercury Hg gauge pressure at the
controller.
-
Sensitive to .1" mercury Hg of vacuum change.
-
Responds to vacuum change in milliseconds.
-
Four models to accommodate different system requirements.
-
American Made
Sentinel
Mark II Vacuum Controller Item# M-407
-
Sensitive to 0.1" Hg change
-
Adjustment range
8" – 15" Hg Differential vacuum
-
Minimum flow while operating: 1 CFM ASME
-
Finish: ABS and Lexan plastics
-
Adjustment knob
-
2" male NPT mounting
-
Size: 6" diameter x 11¼" high
-
Filters: a) Top dome filter, submicron; b) Main filter, sponge type (WDR Part #406-21)
-
Maximum capacity: 150 CFM ASME at 15" Hg
-
Direct Sensing
-
Weight: 1¼ lbs.
-
Nominal Air Pass-by:
N/A (no air pass-by)
-
PEACEKEEPER 462-200: Available noise suppressor with added filtration
-
Worn Parts
Replacement Kit shown here
Sentinel
Model 350 Vacuum Controller Item# M-350
-
Sensitive to 0.1" Hg change
-
Adjustment range 8"–15" Hg Differential
vacuum
-
Reaction time to change: 50 milliseconds or less
-
Finish: Hard anodized aluminum for maximum durability and corrosion resistance.
-
Adjustment screw (with special wrench to restrict unauthorized tampering)
-
3" female NPT mounting
-
Size: 7" diameter x 13¼" high
-
Filters: a) Top dome filter, submicron; b) Main filter, standard cartridge type (WDR Part #AP-58)
-
Mounting: Quick-disconnect stainless steel clamp
-
Maximum capacity: 350 CFM ASME at 15" Hg
-
Direct Sensing
-
Weight: 10 lbs.
-
Nominal Air Pass-by: 15 CFM ASME
-
PEACEKEEPER 462-350: Available noise suppressor with added filtration
Sentinel
Model 500 Vacuum Controller Item#
M-500
-
Sensitive to 0.1" Hg change
-
Adjustment range 8" – 15" Hg Differential
vacuum
-
Reaction time to change: 50 milliseconds or less
-
Finish: Hard anodized aluminum for maximum durability and corrosion resistance
-
Adjustment screw (with special wrench to restrict unauthorized tampering)
-
3" female NPT mounting
-
Size: 7" diameter x 13¼" high
-
Filters: a) Top dome filter, submicron; b) Main filter, standard cartridge type (WDR Part #AP-58)
-
Mounting: Quick-disconnect stainless steel clamp
-
Maximum capacity: 500 CFM ASME at 15" Hg
-
Direct Sensing
-
Weight: 10 lbs.
-
Nominal Air Pass-by: 25 CFM ASME
-
PEACEKEEPER 462-350: Available noise suppressor with added filtration
Sentinel
Model 100 Vacuum Controller Item# M-100
-
Sensitive to 0.1" Hg change
-
Adjustment range 8" – 15" Hg
Differential vacuum
-
Reaction time to change: 50 milliseconds or less
-
Finish: Hard anodized aluminum for maximum durability and corrosion resistance
-
Adjustment screw (with special wrench to restrict unauthorized tampering)
-
1½" female NPT mounting
-
Size: 5" diameter x 12¾" high
-
Filters: a) Top dome filter, submicron; b) Main filter, standard cartridge type (WDR Part# AP-107)
-
Maximum capacity: 150 CFM ASME at 15"
Hg
-
Direct Sensing
-
Weight: 4 lbs.
-
Nominal Air Pass-by: 10 CFM
ASME
-
Peacekeeper 462-100: Available noise suppressor with added filtration
|
For a free copy
of Adobe Acrobat PDF reader software, go here.
To open the PDF formatted file above, click the left mouse
button. To save the PDF formatted file above to your
computer disk, click the right mouse button, then click Save
Target As. |
To Order or for
further information please call
1-800-635-6413 or 949-598-9700
|
Get
an Email right now
regarding our vacuum controllers. Their specifications,
pricing, etc. Click below.
 |
If you would like some particular piece of
information either emailed, faxed or mailed to you, please send us an email with
that request. Go here, thank you.
To purchase online go here -->
 |